Thank you for choosing Athena Controls. Congratulations on your purchase.
Used properly, this precision instrument will provide you with many years of
trouble-free and productive service.
The RMB Series zone controllers offer many advanced features designed to
increase productivity and ensure fast, accurate and repeatable mold
temperature control.
! Compatible with all previous G
1
and G+ units and all existing Hot
Runner Controls for easy retrofit/replacement.
! Simultaneous display of both process/setpoint temperature and
process temperature/percent power output or heater current.
! Autotuning independently adjusts zone control characteristics.
! Built-in diagnostics alert operator to fault conditions.
! CompuStep
®
circuitry provides for safe heater warm-up through
gradual phase angle-fired voltage control (Soft Start).
While most technical questions concerning the operation of the Series RMB
controllers can be answered by referring to this manual, you may contact
your Athena representative for additional support, or Athena Customer
Service directly, at 800-782-6776 (outside the U.S. call 610-828-2490).
Introduction
Precautions
After unpacking, inspect the instrument for any physical damage that may
have occurred in shipping. Save all packing materials and report any
damage to the carrier immediately.
NOTES ON CE EMC COMPLIANCE
This unit is compliant with the following standards when properly installed
into a grounded metal housing: (EMC testing was conducted with a load
of 1Amp and setpoint of 400°F.)
EMC Directive (89/336/EEC)
EN 50081-1 (1992 edition)
EN 50082-1 (1992 edition)
Low Voltage Directive (73/23/EEC)
EN 61010-1 (1992 edition, Amendments 1, 2, 3, 4 and 11)
WARNING
This is a Class A product. In a domestic enviroment this product may
cause radio interference in which case the user may be required to take
adequate measures.
1
G is a registered trademark of the DME Corporation.
2 © Copyright 1999, Athena Controls, Inc.
Safety Warning
In addition to presenting a potential fire hazard, high voltage and high
temperature can damage equipment and cause severe injury or death.
When installing or using this instrument, follow all instructions carefully and
use approved safety controls (high limit, etc.). Only suitably trained
personnel should perform electrical wiring of connections.
Do not locate this instrument where it may be subjected to excessive
shock, vibration, dirt, moisture, oil, or other liquids.
Safe operating temperature range is 32 to 131°F (0 to 55°C ).
Never insert or remove a controller from a mainframe with the AC power on.
Hazardous potentials exist on components inside the mainframe and
controller. Always disconnect AC power to the mainframe when servicing!
Because these temperature controls or associated equipment may not
always fail safe, an approved temperature and/or pressure safety control
should be used for safe operation.